力士樂(lè)伺服驅(qū)動(dòng)器專業(yè)維修全系列:作為一種精密儀器,驅(qū)動(dòng)器給常人的感覺(jué)高深,操作起來(lái)不容易,維修起來(lái)更加不容易。但是,對(duì)于一些用戶或者操作人員來(lái)說(shuō),掌握驅(qū)動(dòng)器維修相關(guān)知識(shí)又是一門(mén)必不可少的課程。而且想要學(xué)習(xí)驅(qū)動(dòng)器維修,需要全方位掌握一些技能與知識(shí)。
力士樂(lè)伺服驅(qū)動(dòng)器維修保養(yǎng):F822故障含義:Motor Encoder Failure: Signal too Small電機(jī)編碼器故障:信號(hào)太小
Description:故障說(shuō)明:
The motor encoder signals are monitored. If the signal amplitudes as measured via AK1 and AK2 are outside of the allowable region between Uss = 12.0V and Uss = 18.0 V, then the error message appears. The drive becomes torque-free and an optional brake is immediately activated.監(jiān)控電機(jī)編碼器信號(hào)。如果通過(guò)AK1和AK2測(cè)得的信號(hào)振幅超出Uss=12.0V和Uss=18.0V之間的允許范圍,則會(huì)顯示錯(cuò)誤消息。驅(qū)動(dòng)器變?yōu)闊o(wú)扭矩狀態(tài),并立即啟用可選制動(dòng)器。
Cause:
1. Defective feedback cable.
2. Defective feedback.
1.反饋電纜有缺陷。
2.反饋有缺陷。
Remedy:
1. Check the feedback cable.Lay the power cables separate from the feedback cable.The cable shield must be connected to the drive controller.(See also project reference of the drive control).檢查反饋電纜。將電源電纜與反饋電纜分開(kāi)敷設(shè)。電纜屏蔽必須連接到驅(qū)動(dòng)器控制器。(另請(qǐng)參見(jiàn)驅(qū)動(dòng)控制的項(xiàng)目參考)。
2. Exchange motor.更換電機(jī)。
Note: This error can only be cleared in parametrization mode (phase2). As a result of this error, the encoder emulation is switched off.注:此錯(cuò)誤只能在參數(shù)化模式(第2階段)下清除。由于此錯(cuò)誤,編碼器仿真被關(guān)閉。
轉(zhuǎn)載請(qǐng)注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動(dòng)器維修,伺服電機(jī)維修
本文鏈接:http://xyymjy.com/fuwu/Services_Show12077.htm
伺服驅(qū)動(dòng)器維修 伺服電機(jī)維修 觸摸屏維修 變頻器維修
電話:021-50157782
手機(jī):13817011982 微信同號(hào)
郵箱:shygdzi@163.com
聯(lián)系人:張工
網(wǎng)址:http://xyymjy.com
【 我們確保修好測(cè)試好給客戶。。!】
下一篇:常州INVY英威騰CHE100-011G-2變頻器OC報(bào)警故障維修